SPECIFICATION (Measured at 230Vac, 25℃. Unless otherwise noted)
Item | Specifications |
---|---|
Output Voltage Selectable | 5V; 4.5V; 4.2V; 4V; 3.8V; 3.3V; 2.8V; |
Overload protection | Automatically resume work after the overload fault is eliminated, long-time short-circuit of the output terminal will not be damaged or heated |
Output short circuit protection | Automatically resume work after the output short-circuit fault is eliminated, long-time short-circuit of the output terminal will not be damaged or heated |
Over voltage protection | Prevent from being damaged or burnt due to excessive voltage |
Withstand voltage | IP-OP:3000Vac; IP-PE:1500Vac;OP-PE:500vdc |
Working temperature | -40~70℃ |
Start-up Time | <3Sec |
Safety standards | GB4943/EN60950 |
EMCstandards | IEC61000-4 |
Connection | 9.5mm screw terminial |
Dimension(L*W*H) | 200±1×96±1mm×42±1mm |
Product
Model | Input | Output | Current | Effi | tol | R&N | Temp | PFC | Cert |
---|---|---|---|---|---|---|---|---|---|
LV-260-4.2 | AC200-240V | 4.2V | 50A | 87% | ±3% | <200mV | -40-70℃ | / | / |
LV-260-4.5 | AC200-240V | 4.5V | 50A | 88% | ±3% | <200mV | -40-70℃ | / | / |
LV-260-5 | AC200-240V | 5.0V | 50A | 90% | ±3% | <200mV | -40-70℃ | / | / |
SPECIFICATION (All the parameters are measured under
230VAC input,more than 10% of rated load,and 25℃ of ambient temperature.)
Item | Specifications |
---|---|
Output Voltage | 5V; 4.5V; 4.2V; 4V; 3.8V; 3.3V; 2.8V; |
Overload protection | Built-in |
Short circuit protection | Hiccup mode, recovers automatically after fault condition is removed |
Over voltage protection | Built-in |
Withstand voltage | IP-OP:3000Vac; IP-PE:1500Vac;OP-PE:500vdc |
Working temperature | -40~70℃ |
Start-up Time | <3Sec |
Safety standards | GB4943/EN60950 |
EMCstandards | IEC61000-4 |
Connection | 9.5mm screw terminial |
Dimension(L*W*H) | 200±1×97±1mm×50±1mm |
Model List
Model | Input | Output | Current | Effi | tol | R&N | 工Temp | PFC | Cert |
---|---|---|---|---|---|---|---|---|---|
LV-200-4.2 | AC200-240V | 4.2V | 40A | 87% | ±3% | <200mV | -40-70℃ | / | / |
LV-200-4.5 | AC200-240V | 4.5V | 40A | 88% | ±3% | <200mV | -40-70℃ | / | / |
LV-200-5 | AC200-240V | 5.0V | 40A | 90% | ±3% | <200mV | -40-70℃ | / | / |
- Semi-Potted rainproof power supply
- Patented design Intelligent loading instruction
- Special seamless rainproof structure to prevent rain and water spray
- Synchronous rectification, conversion efficiency up to 94%, more energy-saving and power-saving
- Fan-less, no-noise working, long life span
- Overcurrent protection, short circuit protection, prevent wire short circuit and fire
SPECIFICATION (Measured at 230Vac, 25℃. Unless otherwise noted)
Item | Specifications |
---|---|
Output Voltage Selectable | 12V;24V |
Overload protection | Automatically resume work after the overload fault is eliminated, long-time short-circuit of the output terminal will not be damaged or heated |
Output short circuit protection | Automatically resume work after the output short-circuit fault is eliminated, long-time short-circuit of the output terminal will not be damaged or heated |
Over voltage protection | Prevent from being damaged or burnt due to excessive voltage |
Withstand voltage | IP-OP:3000Vac; IP-PE:1500Vac;OP-PE:500vdc |
Working temperature | -40~70℃ |
Start-up Time | <3Sec |
Safety standards | GB4943/EN60950 |
EMCstandards | IEC61000-4 |
Connection | 9.5mm screw terminial |
Dimension(L*W*H) | 232.5±1mm120±1mm40.7±1mm |
Product
Model | Input | Output | Current | R&N | Effi | Temp | Storage temperature |
---|---|---|---|---|---|---|---|
CXF-400-12 | AC200-240V | 12V | 33A | <200mV | 92% | -40-70℃ | -40℃-85℃ |
CXF-400-24 | AC200-240V | 24V | 16.7A | <200mV | 94% | -40-70℃ | -40℃-85℃ |
- Special for fixed display
- Wide input voltage range, strong adaptability
- -40℃~+70℃ wide working temperature
- According to US standard: UL60950
- Using top brand components, better quality
- 100% full-load aging at high temperature , low failure rate and high reliability
- With auto power factor correction circuit, no interfere to the grid, energy and power saving
SPECIFICATION (Measured at 230Vac, 25℃. Unless otherwise noted)
Item | Specifications |
---|---|
Output Voltage Selectable | 5V; 4.5V; 4.2V |
Overload protection | Automatically resume work after the overload fault is eliminated, long-time short-circuit of the output terminal will not be damaged or heated |
Output short circuit protection | Automatically resume work after the output short-circuit fault is eliminated, long-time short-circuit of the output terminal will not be damaged or heated |
Over voltage protection | Prevent from being damaged or burnt due to excessive voltage |
Withstand voltage | IP-OP:3000Vac; IP-PE:1500Vac;OP-PE:500vdc |
Working temperature | -40~70℃ |
Start-up Time | <3Sec |
Safety standards | GB4943/EN60950 |
EMCstandards | IEC61000-4 |
Connection | 9.5mm screw terminial |
Dimension(L*W*H) | 199±1×99±1mm×30±1mm |
Product
Model | Input | Output | Current | Effi | tol | R&N | Temp | PFC | Cert |
---|---|---|---|---|---|---|---|---|---|
HTU-400-4.2 | AC100-240V | 4.2V | 80A | 88% | ±3% | <200mV | -40-70℃ | √ | CE |
HTH-400-4.2 | AC200-240V | 4.5V | 80A | 86% | ±3% | <200mV | -40-70℃ | Χ | / |
HTU-400-4.5 | AC200-240V | 5.0V | 80A | 90% | ±3% | <200mV | -40-70℃ | √ | CE |
HTH-400-4.5 | AC200-240V | 4.2V | 80A | 88% | ±3% | <200mV | -40-70℃ | Χ | / |
HTU-400-5 | AC200-240V | 4.5V | 80A | 92% | ±3% | <200mV | -40-70℃ | √ | CE |
HTH-400-5 | AC200-240V | 5.0V | 80A | 90% | ±3% | <200mV | -40-70℃ | Χ | / |
- Special for fixed display;
- Wide input voltage range, strong adaptability
- -40℃~+70℃ wide working temperature
- According to US standard: UL60950
- Using top brand components, better quality
- 100% full-load aging at high temperature , low failure rate and high reliability
- With auto power factor correction circuit, no interfere to the grid, energy and power saving
SPECIFICATION (Measured at 230Vac, 25℃. Unless otherwise noted)
Item | Specifications |
---|---|
Output Voltage Selectable | 5V; 4.5V; 4.2V |
Overload protection | Automatically resume work after the overload fault is eliminated, long-time short-circuit of the output terminal will not be damaged or heated |
Output short circuit protection | Automatically resume work after the output short-circuit fault is eliminated, long-time short-circuit of the output terminal will not be damaged or heated |
Over voltage protection | Prevent from being damaged or burnt due to excessive voltage |
Withstand voltage | IP-OP:3000Vac; IP-PE:1500Vac;OP-PE:500vdc |
Working temperature | -40~70℃ |
Start-up Time | <3Sec |
Safety standards | GB4943/EN60950 |
EMCstandards | IEC61000-4 |
Connection | 9.5mm screw terminial |
Dimension(L*W*H) | 199±1×99±1mm×30±1mm |
Product
Model | Input | Output | Current | Effi | tol | R&N | Temp | PFC | Cert |
---|---|---|---|---|---|---|---|---|---|
HTU-300-4.2 | AC100-240V | 4.2V | 60A | 88% | ±3% | <200mV | -40-70℃ | √ | CE |
HTH-300-4.2 | AC200-240V | 4.5V | 60A | 86% | ±3% | <200mV | -40-70℃ | Χ | / |
HTU-300-4.5 | AC100-240V | 5.0V | 60A | 88% | ±3% | <200mV | -40-70℃ | √ | CE |
HTH-300-4.5 | AC200-240V | 4.2V | 60A | 90% | ±3% | <200mV | -40-70℃ | Χ | / |
HTU-300-5 | AC100-240V | 4.5V | 60A | 90% | ±3% | <200mV | -40-70℃ | √ | CE |